The maximum opening force for sliding and folding doors is also 5 pounds.
Ibc sliding door force.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Opening force opening force for manually operated sliding and folding doors is limited to 5 pounds of opening force maximum.
For other swinging doors as well as sliding and folding doors the door latch shall release when subjected to a 15 pound 67 n force.
Be 1010 1 3 1 location of applied forces.
This limitation does not include the force required to release the lock or latch.
So for an icu door its breakaway panels only open 90 degrees.
Note that the maximum forces allowed by the ibc 2003 for an egress door are 15 pounds to release the latch 30 pounds to set the door in motion and 15 pounds to swing the door to the full open position 1008 1 2.
Both standards note that the 5 pound force limitation does not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position refer to this decoded article for more information on the forces for operable hardware.
This means the width of the panel can only encroach 7 into the standard 8 foot wide corridor.
Sliding or folding doors 5 pounds of force.
The ibc and nfpa 101 says a door at its fully open position cannot encroach more than 7 into the minimum requiredcorridor width.
The door shall swing to a full open position when subjected to a 15 pound 67 n force.